Comparaison des versions

Légende

  • Ces lignes ont été ajoutées. Ce mot a été ajouté.
  • Ces lignes ont été supprimées. Ce mot a été supprimé.
  • La mise en forme a été modifiée.

Inclure page
_head-en
_head-en

Button Hyperlink
iconbuild
titleFrançais
typeprimary
urlhttps://wiki.umontreal.ca/pages/viewpage.action?pageId=193498625


Tabs Container
idInstrument Tabs
titleZeiss Axio-Observer Z1 Spinning disk
directionhorizontal


Tabs Page
idDescription
titleDescription

Zeiss Axio-Observer Z1 spinning disk confocal fully motorized inverted microscope

Roger Gaudry B-301

  • See

    Link in New Window
    iconfalse
    linkTextdetails
    hrefhttps://biochimie.umontreal.ca/plateformes-scientifiques-bmm/microscopie/microscope-zeiss-axio-observer-z1-avec-disque-rotatif/
    target_blank
    on the
    Link in New Window
    iconfalse
    linkTextBiochemistry Department Microscopy Platform
    hrefhttps://biochimie.umontreal.ca/plateformes-scientifiques-bmm/microscopie/
    target_blank

  • Training and booking available upon request to the corresponding the platform manager

  • Consult the
    Link in New Window
    iconfalse
    linkTextfees structure
    hrefhttps://biochimie.umontreal.ca/wp-content/uploads/sites/37/2021/02/Tarifs_2021-22_pour_utilisation_des_plateformes_BMM.pdf
    target_blank
    and
    Link in New Window
    iconfalse
    linkTextaccess policies
    hrefhttps://biochimie.umontreal.ca/wp-content/uploads/sites/37/2021/10/Reglements_microscopes_oct_2021.pdf
    target_blank
    of the
    Link in New Window
    iconfalse
    linkTextBiochemistry Department Microscopy Platform
    hrefhttps://biochimie.umontreal.ca/plateformes-scientifiques-bmm/microscopie/
    target_blank


Tabs Page
idLog
titleLog


UI Expand
titleTo do
Check Loss of 488nm laser power


UI Expand
title2021-11-20
  • Zen 2.6 updated hotfix 12
  • Microsoft Windows update
  • Laser output measured in spinning disk mode at the sample with 10x objective, 1x Extended tubelens, 100% laser power and ALL lasers ON:
    • 405nm: 1.08 mW StdDev 0.01mW
    • 488nm: 3.3 mW  StdDev <0.01mW (3.7 mW if laser 405 is OFF)

      Avertissement
      title405nm and 488nm Interactions

      When both 405nm and 488nm laser are ON simultaneously, the output power is decreased by 11%.


    • 561nm: 2.6 mW StdDev <0.01mW
    • 639nm: 1.37 mW StDev 0.02 mW
  • Control for vibrations during construction work on the 4th floor


UI Expand
title2021-11-03
  • Error when the definite focus is used (unexpected error the definite focus did not respond)
  • To solve it:
    • Turn off the Zen Software
    • Turn off the microscope power bar (#3)
    • Turn off the definite focus by pressing and holding the definite focus button
    • Turn on the definite focus by pressing once the definite focus button
    • Wait until the definite focus display shows "Detecting stand"
    • Turn on the microscope power bar (#3)
  • Confirm that the definite focus is showing in the microscope tactile display
  • Open Zen software and run an experiment using the definite focus to confirm it is fully functional


UI Expand
title2021-09-27
  • Added to wiki





Tabs Page
idFAQ
titleTroubleshooting & FAQ


UI Expand
titleTroubleshooting



UI Expand
titleFAQ

Can I use this microscope to look at cell in a dish?

  • Yes. This is an inverted microscope designed to look at specimen in a dish or a multi-well plate
  • The objectives are optimized to image through thin glass bottom multi-well plates
  • You may also image specimen mounted between a slide and a 0.17mm thick coverslip





Tabs Container
idDemo Image
titleZeiss Axio-Observer Z1 Spinning disk
directionhorizontal


Tabs Page
idDemo Image
titleDemo Image





Inclure page
Plateformes:_foot-en
Plateformes:_foot-en